Renesas Electronics /R7FA6E2BB /CANFD_B /CFDCFCC

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as CFDCFCC

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (0)CFE 0 (0)CFRXIE 0 (0)CFTXIE 0 (000)CFPLS0 (0)CFM 0 (0)CFITSS 0 (0)CFITR 0 (0)CFIM 0 (000)CFIGCV 0CFTML 0 (000)CFDC0CFITT

CFM=0, CFDC=000, CFIM=0, CFITR=0, CFITSS=0, CFRXIE=0, CFE=0, CFPLS=000, CFTXIE=0, CFIGCV=000

Description

Common FIFO Configuration/Control Register

Fields

CFE

Common FIFO Enable

0 (0): FIFO disabled

1 (1): FIFO enabled

CFRXIE

Common FIFO RX Interrupt Enable

0 (0): FIFO interrupt generation disabled for Frame RX

1 (1): FIFO interrupt generation enabled for Frame RX

CFTXIE

Common FIFO TX Interrupt Enable

0 (0): FIFO interrupt generation disabled for Frame TX

1 (1): FIFO interrupt generation enabled for Frame TX

CFPLS

Common FIFO Payload Data Size Configuration

0 (000): 8 bytes

1 (001): 12 bytes

2 (010): 16 bytes

3 (011): 20 bytes

4 (100): 24 bytes

5 (101): 32 bytes

6 (110): 48 bytes

7 (111): 64 bytes

CFM

Common FIFO Mode

0 (0): RX FIFO mode

1 (1): TX FIFO mode

CFITSS

Common FIFO Interval Timer Source Select

0 (0): Reference clock (× 1 / × 10 period)

1 (1): Bit time clock of related channel (FIFO is linked to fixed channel)

CFITR

Common FIFO Interval Timer Resolution

0 (0): Reference clock period × 1

1 (1): Reference clock period × 10

CFIM

Common FIFO Interrupt Mode

0 (0): RX FIFO mode: RX interrupt generated when Common FIFO counter reaches CFIGCV value from a lower value TX FIFO mode: TX interrupt generated when Common FIFO transmits the last message successfully

1 (1): RX FIFO mode: RX interrupt generated at the end of every received message storage TX FIFO mode: interrupt generated for every successfully transmitted message

CFIGCV

Common FIFO Interrupt Generation Counter Value

0 (000): Interrupt generated when FIFO is 1/8th full

1 (001): Interrupt generated when FIFO is 1/4th full

2 (010): Interrupt generated when FIFO is 3/8th full

3 (011): Interrupt generated when FIFO is 1/2 full

4 (100): Interrupt generated when FIFO is 5/8th full

5 (101): Interrupt generated when FIFO is 3/4th full

6 (110): Interrupt generated when FIFO is 7/8th full

7 (111): Interrupt generated when FIFO is full

CFTML

Common FIFO TX Message Buffer Link

CFDC

Common FIFO Depth Configuration

0 (000): FIFO Depth = 0 message

1 (001): FIFO Depth = 4 messages

2 (010): FIFO Depth = 8 messages

3 (011): FIFO Depth = 16 messages

4 (100): FIFO Depth = 32 messages

5 (101): FIFO Depth = 48 messages

6 (110): FIFO Depth = Reserved

7 (111): FIFO Depth = Reserved

CFITT

Common FIFO Interval Transmission Time